$ 0
0
$ 0
0

Cubex QXR920 10243 Maintenance Manual

Format: PDF (Printable Document)

File Language: English

File Pages: 497

File Size: 37.29 MB (Speed Download Link)

Brand: Cubex

Model: QXR920 10243

Type of Document: Maintenance Manual

Category:

$ 45

Share:

Cubex QXR920 10243 Surface Drill Maintenance Manual

Cubex QXR920 10243 Maintenance Manual

📘 Show Index

Cubex QXR920 10243 Index:

  • 1.1 Operating/Maintenance Safety
    • Drill Operation and Maintenance Safety
    • General Safety Instructions
    • Safety Instructions for Driving and Operating
    • Safety Instructions for Servicing
    • Extinguishing Fires
  • 2.1 Drill Assembly
  • 2.2 Break-in Maintenance
  • 2.3 Preventative Maintenance Program
    • 2.3.1 Lubrication
      • 2.3.1.1 Rock Drill Grease
      • 2.3.1.2 Lubrication Points and Intervals
      • 2.3.1.3 Lubrication Types
      • 2.3.1.4 Lubrication Cross-over
    • 2.3.5 Centralized Machine Lubrication
      • Greaser Assembly
    • 2.3.2 Bolt Torque
    • 2.3.3 Drill Filtration Points and Intervals
    • 2.3.4 Pipe Thread Grease Pump
      • Preventative Maintenance Tasks
      • 2.3.4.1 Safety
      • 2.3.4.2 Maintenance
  • 2.4 Recommended Tools:
  • 3.1 Track Adjustment
  • 3.2 Final Drive
  • 4.1 Mast Feed System
    • 4.1.1 QXR Feed Chain Adjustment
    • 4.1.2 Slider Adjustment
    • 4.1.3 Carrier Block
    • 4.1.4 Feed Chain Block
    • 4.1.5 Jib Boom
    • 4.1.6 Triple Jaw Breakout (TJBO)
      • 4.1.6.1 Overhaul procedure
  • 4.2 Top Drive
    • 4.2.1 Checking Bearing Pre-load
    • 4.2.2 Adjusting Bearing Pre-load
    • 4.2.3 Removing Top Drive
      • 4.2.3.1 Using the Right Equipment
    • 4.2.4 Disassembly Procedure
    • 4.2.5 Installation of Pinion Gears and Bearings
    • 4.2.6 Driveshaft Assembly and Installation
    • 4.2.7 Setting Bearing Preload
    • 4.2.8 Installing Upper Seal and Housing
    • 4.2.9 Installing Air Swivel and Hydraulic Motors
    • 4.2.10 Saver Sub
      • 4.2.10.1 Removal
      • 4.2.10.2 Installation
    • 4.2.11 Air Swivel
      • 4.2.11.1 Removing Air Swivel
      • 4.2.11.2 Installation of Air Swivel
      • 4.2.11.3 Dismantling Air Swivel
      • 4.2.11.4 Inspection of Parts
      • 4.2.11.5 Assembly Procedure
  • 4.3 Top Drive Motor
  • 4.4 Breakout Wrench
  • 4.5 Carousel Assembly
    • 4.5.1 Carousel Adjustment
      • 4.5.1.1 Pipe Clamp Adjustment
      • 4.5.1.2 Clamp Arm Adjustment
  • 4.6 Expander Pin System – Mast Boom
    • 4.6.1 Torque and Maintenance Intervals
      • 4.6.1.3 Torque Schedule
      • 4.6.1.4 Mounting/Dismounting Tools
      • 4.6.1.5 Installation
      • 4.6.1.6 Dismounting
  • 5.1 Hydraulic Symbols
    • 5.1.1 Hydraulic Schematic
  • 5.2 Hydraulic Circuits
  • 5.3 Hydraulic Pump
    • 5.3.1 Adjustments and Maintenance
    • 5.3.2 Factors Affecting the Pump’s Life
      • 5.3.2.1 Contaminated Fluid
      • 5.3.5.2 Poor Suction Conditions
      • 5.3.5.3 Excessive Case Pressure
      • 5.3.5.4 Too Low an Operating Pressure
      • 5.3.5.5 Cavitation/Aeration
  • 5.4 Hydraulic Cylinders
    • 5.4.1 Double Acting Cylinders
    • 5.4.2 Cylinder Inspection
    • 5.4.3 Cylinder Overhaul
  • 5.5 Control Valves – On/Off Types
    • 5.5.1 Control Valves
    • 5.5.2 Relief Valve Adjustment
    • 5.5.3 Valve Pressure Adjustment
    • 5.5.4 Valve Flow Adjustment
    • 5.5.5 Valve Overhaul
    • 5.5.6 Valve Sections
    • 5.5.7 Solenoid
    • 5.5.8 Lever Section
    • 5.5.9 Valve Assembly
    • 5.5.10 Inlet Section
  • 5.6 Manifold Blocks
    • 5.6.1 Servicing Cartridge Valves
    • 5.6.2 Troubleshooting Cartridge Valves
    • 5.6.3 Installation Torque Values
  • 5.7 Counterbalance Valves
    • 5.7.1 Making Adjustments
    • 5.7.2 Troubleshooting
  • 5.8 Hydraulic Filtration
    • 5.8.1 Change Hydraulic Fluid Every 2000 Hours
    • 5.8.2 Return Filters
    • 5.8.3 Pressure Filter Element
  • 5.9 Proportional Valves
    • 5.9.1 Proportional Valve Settings
    • 5.9.2 Flow Settings
    • 5.9.3 Pressure Setting
  • 6.1 Air Schematic
  • 6.2 Sullair Compressor
    • 6.2.1 Compressor Unit Functional Description
    • 6.2.2 Compressor Discharge System Functional Description
    • 6.2.3 Compressor Cooling and Lubrication System Functional Description
    • 6.2.4 Air Inlet System Functional Description
    • 6.2.5 Lubrication Guide
    • 6.2.6 Application Guide
    • 6.2.7 Control System
      • 6.2.7.1 Purpose of Controls
      • 6.2.7.2 Butterfly Inlet Valve Functional Description
      • 6.2.7.3 Closed Inlet Start Program
      • 6.2.7.4 Normal Operation
      • 6.2.7.5 Modulation
      • 6.2.7.6 Unload
      • 6.2.7.7 Compressor Start Up Mode and Running Mode Low Air Pressure
      • 6.2.7.8 Manual Unload Mode
      • 6.2.7.9 Running Mode 350 psi Air Pressure
      • 6.2.7.10 Running Mode 500 psi Air Pressure
      • 6.2.7.11 Instrumentation and Protection
      • 6.2.7.12 Start Up and Shutdown Procedures
      • 6.2.7.13 Adjustment Procedures
    • 6.2.8 Compressor Maintenance
      • 6.2.8.1 Main Fluid Filter Service
      • 6.2.8.2 Thermal/Bypass Valve
      • 6.2.8.3 Separator Element Replacement
      • 6.2.8.4 Running Blowdown Valve Maintenance
      • 6.2.8.5 Shutdown Blowdown Valve Maintenance
      • 6.2.8.6 Minimum Pressure/Check Valve Maintenance
      • 6.2.8.7 Discharge Check Valve Maintenance
      • 6.2.8.8 Safety Valve
      • 6.2.8.9 Pressure Regulator (Low / High Air Pressure Regulator)
      • 6.2.8.10 Fluid Stop Valve
    • 6.2.9 Screw Compressor
      • 6.2.9.1 Screw Compressor Arrangement
      • 6.2.9.2 Compressor Operator Daily Checklist
      • Compressor Operator Daily Checklist
      • 6.2.9.3 Maintenance Schedules
      • 6.2.9.4 Compressor Lubrication Crossover
      • 6.2.9.5 Compressor Troubleshooting
  • 6.3 Water Pump
    • 6.3.1 Pump Speed Adjustment
    • 6.3.2 Dismantling of Valves
    • 6.3.3 Assembling of Valves
    • 6.3.4 Dismantling the Pumping Section
    • 6.3.5 Pump Assembly
    • 6.3.6 Removing Sleeves and Seals
    • 6.3.7 Installing Sleeves and Seals
    • 6.3.8 Servicing the Crankcase
    • 6.3.9 Pump Installation
  • 6.4 Grease Injection
    • 6.4.1 To Fill Reservoir
    • 6.4.2 To Prime System
    • 6.4.3 Operation
    • 6.4.4 Adjusting Flow Rate
      • 6.4.4.1 Setting for a 4” Hammer
      • 6.4.4.2 Setting for a 6” Hammer
    • 6.4.5 PanelView Settings for QXR
  • 7.1 Electrical Circuits
  • 7.2 Electrical Components
  • 7.3 On/Off Valve Activation
  • 7.4 Types of Valves
  • 7.5 Testing of Valve Solenoids
  • 7.6 Testing On/Off Valves
  • 7.7 Proportional Valves
  • 7.8 Fault Monitoring System
    • 7.8.1 Testing Proportional Valves
  • 7.9 Accra-Feed PLC System
    • 7.9.1 Accra-Feed Operation
    • 7.9.2 Accra-Feed Components
    • 7.9.3 PLC Operation
    • 7.9.4 Maintenance of PLC in Accra-Feed System
    • 7.9.5 Troubleshooting Guide
  • 7.10 Operator Interface PanelView 1000
    • 7.10.1 Maintenance of PanelView Terminal
    • 7.10.2 Troubleshooting PanelView Terminal
    • 7.10.3 Alarm Messages on the Terminal
  • 8.0 Troubleshooting
  • 8.1 Troubleshooting Mechanical Systems
    • Tramming does not move or move straight
    • Tramming is too slow or lacks power
    • Brakes are slipping
    • Excessive noise or vibration when tramming
    • Mast swing does not rotate
    • Mast rotates erratically or rotates after setting
    • Mast rocks back and forth
    • Hydraulic cylinders not operating
    • Cylinder creep
    • Centralizer does not retract
    • Oil leakage at stinger cylinder
    • Pulldown control does not function correctly
    • Holdback control does not function correctly
    • Top drive does not rotate, or rotation is slow or rough
    • Rotation and Feed joysticks produce uneven speeds in both directions
  • 8.2 Troubleshooting Hydraulic Systems
    • Fluid is hot
    • System is noisy
    • Fluid quickly contaminates
    • Fluid is foaming
    • Valve Solenoid Malfunction
    • Insufficient pressure or flow
    • Pump is noisy or vibrates
    • Pump does not run
    • Hydraulic motors or cylinders do not respond
    • Rotation and Feed joysticks produce uneven speeds in both directions
  • 8.3 Troubleshooting Air Systems
    • Air pressure is zero or low
    • Water pump pressure is zero
    • Water pump pressure is low
    • Water pump runs extremely rough
    • Water pump leaking
    • Grease delivery is incorrect
  • 8.4 Troubleshooting Electrical Systems
    • Engine does not start
    • Tram controls (joysticks only) are insensitive
    • Hydraulic motors or cylinders not operating
    • Rotation and Feed joysticks produce uneven speeds in both directions
    • Valve Solenoid Malfunction

Cubex

Latest Product

0
    0
    Your Cart
    Your cart is emptyReturn to Shop