On a site where power can’t go down—hospitals, data rooms, pump stations—this KSE TS 880 is the box that decides when to jump from utility to generator and back. This manual is what I’d keep on the bench to walk through how the switch should behave, then trace where it’s not. If the switch hangs in one position after a power outage, I’d use this to verify control signals, check mechanical interlocks, and confirm settings before blaming the controller or swapping parts.

Applications & Use Cases

  • Trace transfer faults step by step so you can prove whether the issue is in sensing, control wiring, or the power mechanism.
  • Verify proper installation: line/load routing, grounding, and clearances before first energizing the switch.
  • Isolate nuisance trips or failed transfers by following the documented operating logic instead of guessing.
  • Guide disassembly/reassembly of contactors and linkages so everything realigns and operates smoothly after repair.
  • Confirm and fine‑tune adjustments like timing and operational settings after component replacement or upgrades.

FAQ

Q: Can I keep this manual on a tablet in the field?

A: Yes, it’s practical to use digitally so you can zoom wiring details and search terms while standing at the switch.

Q: Should I still print parts of it?

A: Many techs print the key procedures or diagrams they use often, then keep the full manual digital for quick lookup.

Safety Note

Always lock out both utility and generator sources and verify absence of voltage before opening or servicing the transfer switch.

📘 Show Index

Kohler KSE TS 880 Automatic Transfer Switches Operation, Installation, Index:

Product Identification Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Precautions and Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
List of Related Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Service Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Section 1 Equipment Description and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2 Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4.1 Equipment Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4.2 Equipment Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Section 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Upstream Circuit Protective Devices/Electrical Connections . . . . . . . . . . . . . . . . . 11
2.3 Transfer Switches with Integral Overcurrent Protection . . . . . . . . . . . . . . . . . . . . . 12
2.4 Transfer Switches with Multi-Tap Voltage Capability . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5 System Phasing, High Leg Delta Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6 Remote Start Contact Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.7 Dielectric Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.8 Open Type Transfer Switch Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.9 Ground Fault Site Test Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.10 Performance Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.11 Typical Commissioning Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Section 3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1 Normal Sequence of Operation, Open Transition Type Transfer Switches . . . . . 15
3.2 Service Entrance Automatic Transfer Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2.1 Normal Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2.2 Overcurrent Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3 Service Disconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3.1 Service Disconnect Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3.2 Additional Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.4 Test Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Section 4 Overcurrent Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Section 5 Servicing Transfer Switch Mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1 Molded-Case Switch Type Transfer Mechanisms, 100–250 A S-Style . . . . . . . . . 21
5.1.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1.2 Equipment Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1.3 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.1.4 Recommended Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.2 Molded-Case Type Transfer Mechanisms, 400–1200 A . . . . . . . . . . . . . . . . . . . . . 23
5.2.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.2.2 Equipment Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.2.3 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.2.4 Recommended Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.3 Insulated-Case Type Transfer Mechanisms, 800–4000 A . . . . . . . . . . . . . . . . . . . 24
5.3.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.3.2 Equipment Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.3.3 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.3.4 Recommended Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table of Contents, continued
4 Table of Contents TP-6380 8/08
Section 6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1 100–1200 Amp Molded-Case Switch Type ATS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.2 800–4000 Amp Insulated-Case Switch Type ATS . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.3 Power Switching Device
(800–4000 Amp Insulated-Case Switch Type ATS) . . . . . . . . . . . . . . . . . . . . . . . . . 30
Section 7 Diagrams and Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Section 8 Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Section 9 Performance Test Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Appendix A Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Appendix B Commissioning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45