Agco EDT (Electronic Diagnostic Tool) v07.2025

Update: 30.06.2025

Size: 42.50 GB (High Speed Download link)

OS: Win10, win11

Type of Software: Electronic Diagnostic Software

Region: All Region

Interface Language: Danish, Dutch, Finnish, French, German, Italian, Polish, Portuguese (Brazil), Russian, Spanish, Swedish, Turkish, English (US)

Brand: AGCO (Agricultural Machinery)

 

$ 300

Share:

Agco EDT (Electronic Diagnostic Tool) v07.2025

Agco EDT (Electronic Diagnostic Tool) v07.2025

Release Notes AGCO EDT – 6/30/2025 – Update 2025.3.OC1

EDT NOTES:

EDT Version: 1.128.24284.909

Vehicles Affected:

Fendt: 932, 934, 934H, 937, 937H, 937H HT
Vehicle Version:

1.26
Software:

Chassis Controller EXT (v03.04.08):
BUG-20922(PPRP29248) Boom Tilt logic getting stuck on when missing MFA messages
Release Notes – 5/20/2025 – Update 2025.3

EDT NOTES:

EDT Version: 1.128.24284.909

Vehicles Affected:

Challenger: WR9900 Series
Massey Ferguson: WR9900 Series
Vehicle Version:

1.66
Software:

NT03 05.00.14
Upgrade to label 28 software support libraries
Fix guidance pop-up from coming up on ignition
Fix displaying pre-condition for driving with guidance
EXT-Lt 04.01.01
Add support for Label 28 NT03 libraries
ACM 06.00.03
Reduced time to boot
Vehicles Affected:

Massey Ferguson: Square Balers: 2224, 2233, 2234, 2234XD, 2244
Fendt: Square Balers: 990, 1270, 1290, 1290XD, 12130
Vehicle Version:

1.35
Software:

EXT 01.13.01
Fix baler accumulator connection lost alarm
Stacked accumulator starts filling from bottom
Flat accumulator shows unused position as dark grey
Fix displaying certain language strings in case a Cyrillic language is used
Fix crash when input string is not detected as Unicode and string is larger than 16 characters
ACM 06.00.03
Reduced time to boot
Vehicles Affected:

Challenger: 660B made in Brazil, 670B made in Brazil, 680B made in Brazil
Massey Ferguson: 9695 made in Brazil, 9795 made in Brazil, 9895 made in Brazil
Valtra: BC6800, BC7800, BC8800
Vehicle Version:

1.35
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
Vehicles Affected:

Massey Ferguson: 4690, 5690, 6690
Valtra: BC4800, BC5800
Vehicle Version:

3.19
General:

Moved C1000 monitor from guidance to combine diagnostics connection
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
Vehicles Affected:

Massey Ferguson: MF9130, MF9350Dry
Valtra: BS3120H, BS3350H
Vehicle Version:

4.7
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
Vehicles Affected:

Massey Ferguson: 2700-4700 Series
Massey Ferguson: 6700R Series
Massey Ferguson: Global Series 4700-5700-6700
Valtra: A100
Valtra: A100Hitech Series
Valtra: A4, A4S
Valtra: A4Hitech Series
Valtra: AC52.5, AC54.5, AC56.5
Vehicle Version:

7.9
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
Vehicles Affected:

Fendt: Slicer 1010 KC PRO
Fendt: Slicer 1010 KCB
Fendt: Slicer 1010 RC PRO
Fendt: Slicer 1010 RCB
Fendt: Slicer 960 KC PRO
Fendt: Slicer 960 KCB
Fendt: Slicer 960 RC PRO
Fendt: Slicer 960 RCB
Massey Ferguson: DM 10114 TL-KC PRO
Massey Ferguson: DM 10114 TL-KCB
Massey Ferguson: DM 10114 TL-RC PRO
Massey Ferguson: DM 10114 TL-RCB
Massey Ferguson: DM 9614 TL-KC PRO
Massey Ferguson: DM 9614 TL-KCB
Massey Ferguson: DM 9614 TL-RC PRO
Massey Ferguson: DM 9614 TL-RCB
Vehicle Version:

1.3
General:

Fix of EDT script for brand check to allow SW update
Vehicles Affected:

Fella: TS 12545 PRO
Fendt: Former 12545 PRO
Massey Ferguson: RK 1254 TRC-PRO
Vehicle Version:

3.6
General:

New in SW 3.6.0:
manual transport: reuse arm position sensor (if ok) to switch off arm down output below 50%. If sensor not ok: show warning.
show warning for front rakes down in manual transport
add STOP SK to diagnostic SKM
Stop SK: switch to manual transport, also in alarm
manual working: show pop up also after alarm
manual working: add pop up to confirm working/headland position

Software:

3.6.0
Vehicles Affected:

Fella: TS 14055 PRO
Fendt: Former 14055 PRO
Massey Ferguson: RK 1404 TRC-PRO
Vehicle Version:

5.2
General:

Fix EEPROM Adress of LifeTime Variabels
New in SW 4.5.0:
manual transport: reuse arm position sensor (if ok) to switch off arm down output below 50%. If sensor not ok: show warning.
show warning for front rakes down in manual transport
Stop SK: switch to manual transport, also in alarm mask
manual working: show pop up also after alarm
manual working: add pop up to confirm working/headland position
Software:

4.5.0
Vehicles Affected:

Fendt: Former 1000 C PRO
Fendt: Former 920 C PRO
Fendt: Former 860 C PRO
Massey Ferguson: RK 1002 TRC-PRO Gen2
Massey Ferguson: RK 922 TRC-PRO Gen2
Massey Ferguson: RK 862 TRC-PRO Gen2
Vehicle Version:

1.3
General:

Fix of EDT script for brand check to allow SW update
Vehicles Affected:

Fendt: IDEAL Combines
Massey Ferguson: IDEAL Combines
Vehicle Version:

1.119
General:

Bugfix:
Auto Header Tilt Updates: Found an issue in production where header tilt would never stabilize. Updates for Auto header tilt include: – Calibration to start ramping the tilt current at a lower current. – Long drag rod deadband from 2% to 8%. – Short drag rod deadband from 2% to 15%
Harvest Mode Update: Fixed bug where feeder flow bar on Harvest Modes page was always empty.
GDM Software Versioning Update: Fixed issue where EDT would read back the incorrect software version after flashing.
Chaff Spreader Speed Sensor Option Update: 2X part number was tied to incorrect EEPROM location causing it to not get enabled in production.
Software:

EXT ver. EXT_.__CR__.F.13.002.01.
GDM ver. 13.03
NT01 ver. 13_02_25111
Vehicles Affected:

AGCO: DTB Series
Challenger: MT600 C Series, MT600 D Series
Massey Ferguson: 8600 Series
Vehicle Version:

10.61
Plug-Ins:

Update PVED-CL plugin to V5.22 :
Added Capability for the PVED_CL S7 replacement valve for the PVED_CL S4
Removed a SW Version check from the PVED_CL Steering Calibration diagnostic surface which was obsolete and didn’t work with the new S7 SW version
Fix issue that the steering valve could not be positioned back to the center position at the end of the right deadband calibration
Vehicles Affected:

Massey Ferguson: 530R
Massey Ferguson: 535R
Valtra: R530
Valtra: R535
Vehicle Version:

2.2
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
Vehicles Affected:

Fendt: 932, 934, 934H, 937, 937H, 937H HT
Vehicle Version:

1.25
General:

Error codes will now appear on the Active Errors and Stored Errors pages with correct definitions.
Spinner box type selection page added to select between NL4500G4/NL5000G5 and NL720 spinner boxes. Chassis EXT controller gets updated accordingly when performing a software flash depending on the spinner box type selected.
Fixed 3rd guidance option not showing up on page in specific R9 configuration
EDT will now automatically detect the tire/drive package if a 934/934H model is selected
EDT will now automatically detect the extreme hill climb package if a 937/937H model is selected
NT01 display is now referred to as “VarioTerminal” to align with Fendt brand
Diagnostics:

Additional information for troubleshooting added to “Engine Fan Control” diagnostic page
Improvements made to “Left Side of Dash” diagnostic page
Improvements made to “Right Side of Dash” diagnostic page
Calibrations:

Multiple improvements made to drive pump and wheel motor calibration page. Calibration finished indicators and calibration error indicators will now appear on page correctly.
Configuration:

Improvements made to how EDT reads and applies updated NT01 .ini files for the VarioTerminal Database Configuration function. EDT will more consistently finish .ini file flash attempts successfully.
Additional options added to VarioTerminal Database Configuration function including “Fan Reversal” and “High Clearance”.
Added the Set Dash Hours configuration procedure.
The four wheel steer disengage speed can now be changed on the “Four Wheel Steer Configuration” page when connection “Chassis and Steering Diagnostics (3 of 4)” is selected.
Using the “Read/Change System EXT Configuration” function to change the liquid system option “Raven XRT” will now correctly update the liquid system controller.
Software:

The “NEW TERMINAL” NT01 software flash option now works properly.
Chassis Controller EXT (v03.04.07):

MC-27042 Add longer timeout for gdAlive processing for 18.1.7F error
MC-20493 performance improvements
BUG-14054 TSC1 and CM1 messages not sending on startup after machine left in accessory mode
Base EEPROM changes:
NONE
Liquid System Controller EXT (v03.01.00):

No changes – same version as previous
Base EEPROM changes:
Changes made to improve boom folding performance
Raven RS1 (v25.1.1.3):

NEW FEATURES

Added Compass Calibration for magnetometer direction sense
ENHANCEMENTS

Improved Guidance Icon lag (COG) when 4WS mode is available
Improved steering performance when paired with EEProm update
Added language support for Croatian, Danish, Estonian, Finnish, Greek, Latvian, Lithuanian, Norwegian, Polish, Romanian, Serbian, Slovak, Slovenian, Swedish, and Turkish
Added disk space popup message and DTC if memory reaches 80% full
Added warning in RS1 if downgrading software
BUG FIXES

Fix for Rogator B not paring with Danfoss Valve
Fix for potential SBAS convergence issue when creating a new profile
Raven RCM-U – Firmware (v25.1.1.25)

NEW FEATURES

Volume Per time message
Dual PWM control allows Minimum PWM for Left and Right
Bin level over CAN for Ultrasonic Sensors
ENHANCEMENTS

Improvements to user experience when adjusting look-ahead by section parameters in Precision Farming setup
Updated PWM limit test for dual control configurations to be able to set limits for each actuator individually
BUG FIXES

Fixed issue with low end PWM valve control where duty cycle was not appropriately ramping up if PWM minimum is set too low
Fixed Manual Control displayed rate issue
Fixed Spreader Constant when multiple sections configured with Dual PWM control
Fixed Low Bin alarm for 3rd bin
Added pin number to pin config error
OTHER

Added support for ISO class 3 speed control for liquid slurry draggling operation when paired with CNH tractors
Added test for calibrating gyroscope to improve performance of turn compensation functionality when not using RS1 Yaw Rate
DEFECT RESOLUTION

Fixed issue with intelligent rate smoothing for granular products with multiple meters
Fixed issue with NH3 boost pump defaults not getting reset properly causing incorrect settings to be used
Vehicles Affected:

Fendt: 5255 L, 5255 L PL, 6275 L, 6275 L PL, 5275 C, 5275 C SL 5275 C PL, 5275 C PLI, 6335 C, 6335 C PL, 6335 C PLI
Laverda: M 300, M 300 LC, M310, M310 LC, M 400, M 400 LC, M 400 LCI, M410, M410 LC, M410 LCI
Massey Ferguson: 7345 S, 7345 S PL, 7347 S, 7347 S PL, 7360, 7360PL, 7360 PLI, 7370, 7370 PL, 7370 PLI, 7360 AL 4
Vehicle Version:

0.91
General:

Fixed the forcing outputs of the “grain tank raising” function in EDT for models: 5275C, 6335C, 7360, 7370
Vehicles Affected:

Gleaner: T61, T71, T81
Vehicle Version:

1.7
General:

Update Engine software for new calibration for Stage 5 MAF sensor.
EXT aligned with the Sx9
Added Portuguese (Brazil) language
Software:

Engine spec. 98722 ver. ACX351691A_1
Engine spec. 98724 ver. ACX351692A_1
Vehicles Affected:

Valtra: BH G4, BH214 Hitech, BH224 Hitech
Vehicle Version:

3.25
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
Vehicles Affected:

Valtra: T4-series 1A7 / 1B8, N4-series 1B7 / 1C8
Vehicle Version:

1.110
Software:

Engine SW:
New EAT Heat calibrations for T4Final engines to avoid SCR efficiency problems
T144 A/H/V/D
T154 A/H/V/D
T174 EA/EH/EV/ED
T194 A/H/V/D
T214 A/H/V/D
T234 A/H/V/D
T254 A/H/V
Vehicles Affected:

Massey Ferguson: 197, 235, 265
Vehicle Version:

1.44
Software:

Main Controller v5.08.01 / 4.05.00
Implement logic block to purge the hydraulic system when an electrical disconnect is detected (v5.08.01 only)
Fix displaying pre-condition for driving with guidance
Ground Drive v5.03.00
Add support for MY26 machines
NT03 v5.00.14
Upgrade to Label 28
Implement user feedback when Header Purge is running
Translation fixes
Fix precondition pop-up in dual screen configuration
Fix displaying pre-condition for driving with guidance
Fix swath overlap setting not being applied (PPR 29013)
Fix wayline and steering sensitivity setting not displaying at startup (PPR 29013)
EXT-Lt v4.07.01
Fix displaying header ID in EDT
EEM4 v1.2.22
Add support for MY26 windrowers.
Vehicles Affected:

Challenger: MT400E Series
Challenger: MT500E Series
Iseki: i5700 Series
Iseki: i6700 Series
Iseki: i7700 Series
Massey Ferguson: 5700S Series
Massey Ferguson: 5700SL Series
Massey Ferguson: 6700S Series
Massey Ferguson: 7700 Made in Brazil Series
Massey Ferguson: 7700 Series
Massey Ferguson: 7700S Series
Valtra: T195-250 Series
Vehicle Version:

8.42
General:

Fix duplication of NT03 standalone display on Network scan and Flash
Software:

ACM SW v06.00.03 for SA machines
Plug-Ins:

ACM Plugin to version 6.22
PVED-CL Plugin to version 5.22:
Add back the picture to help powering ON the PVED-CL during its configuration, this disappeared in a past update