Kohler KBS, KBP, KCC, KBC, KCS, KCP Automatic Transfer Switches Service Manual (tp6460)

Format: PDF (Printable Document)

File Language: English

File Pages: 208

File Size: 8.79 MB (Speed Download Link)

Brand: Kohler

Model: KBS, KBP, KCC, KBC, KCS, KCP Automatic Transfer Switches

Book No: tp6460

Type of Document: Service Manual

Categories: ,

$ 40

Share:

Kohler KBS, KBP, KCC, KBC, KCS, KCP Automatic Transfer Switches Service Manual (tp6460)

Kohler KBS, KBP, KCC, KBC, KCS, KCP Automatic Transfer Switches Service Manual (tp6460)

These Kohler automatic transfer switches live in electrical rooms, plant rooms, and outside enclosures, quietly moving a facility from utility power to generator when the grid drops. This service manual is what I grab when I need to trace a no-transfer complaint or verify the switch is actually at fault before we blame the generator or utility feed. It walks you through logical checks so you can confirm a control, sensing, or mechanical problem instead of just throwing parts at it.

Applications & Use Cases

  • Diagnose “no transfer” or “no retransfer” issues by following step-by-step checks on sensing, controls, and mechanism movement.
  • Isolate nuisance trips or misoperations by comparing real-world readings to the expected behavior described in the manual.
  • Disassemble and reassemble operating mechanisms in the right order so linkages, springs, and interlocks go back aligned and safe.
  • Adjust mechanical and electrical settings after repairs so the switch transfers cleanly under load.
  • Verify wiring changes or retrofits by tracing control circuits and confirming proper routing and terminations.

FAQ

Q: Can I keep this manual on a tablet in the switch room?

A: Yes, it’s practical to use digitally; you can zoom in on diagrams and search text while you’re in front of the gear.

Q: Is it worth printing parts of it?

A: I like to print the procedures and diagrams I use often, slip them in plastic sleeves, and keep them in the panel or service truck for quick reference.

Safety Note

Always lock out all power sources and confirm zero energy before opening or working inside any transfer switch.

📘 Show Index

Kohler KBS, KBP, KCC, KBC, KCS, KCP Automatic Transfer Switches Index:

Safety Precautions and Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
List of Related Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Service Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Model Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Section 1 Scheduled Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 General Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.3 Internal Inspections and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.4 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.4.1 Weekly Generator Set Exercise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.4.2 Monthly Automatic Operation Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.4.3 Other Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.5 Service Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Section 2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.1 Initial Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.2 View Event History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.3 Data Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.4 System Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.4.1 Verify Power to ATS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.4.2 Source Voltage, Frequency, and Phase Rotation Checks . . . . . . . . . . . . 25
2.4.3 Controller Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.5 System Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.5.1 Controller Source Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.5.2 Voltage and Frequency Pickup and Dropout Settings . . . . . . . . . . . . . . . 27
2.6 Time Delays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.7 Reset Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.1 Reset Maintenance Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.2 Reset Event History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.3 Reset Default Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.4 Reset and Disable Test Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.5 File Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.6 Reset Data Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.8 Warnings and Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.8.1 Fault Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.8.2 Module Status Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.8.3 Module Status Conflict . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
2.9 Common Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.10 Events and Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
2.11 Troubleshooting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
2.12 MPAC 1500 Controller Troubleshooting Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . 43
Section 3 Transfer Switch Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.1 Transfer Switch Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.2 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.3 Solenoid Coil, Rectifier, and Snubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.3.1 Solenoid Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.3.2 Rectifier and Snubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.4 Solenoid Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.4.1 30–1200 Amp and 4000 Amp Standard Transition Models . . . . . . . . . . . 55
3.4.2 1600–3000 Amp Standard-Transition Models . . . . . . . . . . . . . . . . . . . . . . 56
3.4.3 150–1200 Amp Programmed-Transition Models . . . . . . . . . . . . . . . . . . . 60
3.4.4 1600–3000 Amp Programmed-Transition Models . . . . . . . . . . . . . . . . . . 62
Table of Contents, continued
Table of Contents TP-6460 4/10
3.4.5 150–1200 Amp Closed-Transition Models . . . . . . . . . . . . . . . . . . . . . . . . . 65
3.4.6 1600–3000 Amp Closed-Transition Models . . . . . . . . . . . . . . . . . . . . . . . . 67
Section 4 Controller Test and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.1 User Interface Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.1.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.1.2 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.1.3 Lamp Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.1.4 Pushbuttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.2 Controller Circuit Boards and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
4.3 Controller Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
4.3.1 Controller Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
4.3.2 Controller Powerup Reset Sequence of Operation . . . . . . . . . . . . . . . . . 74
4.3.3 Controller Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.3.4 Powering Controller Directly (Service Kit GM52407) . . . . . . . . . . . . . . . . 75
4.4 System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.4.1 Unloaded System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.4.2 Loaded System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.4.3 Closed-Transition Loaded Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.4.4 Auto-Loaded System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.4.5 Sync Check (closed-transition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.4.6 Test Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.4.7 Test Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
4.5 Exercise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4.5.1 Exercise Scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4.5.2 Stopping an Exercise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4.5.3 Exerciser Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4.6 Engine Start Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
4.7 Controller DIP Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
4.8 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
4.9 Position Microswitch Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
4.10 Programmed-Transition Interface Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
4.11 File Transfer through USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.11.1 Configuration files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.11.2 Loading Settings when Controller is Replaced . . . . . . . . . . . . . . . . . . . . . 87
4.11.3 Data Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
4.11.4 File Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
4.12 Controller Application Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
4.13 Controller Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.13.1 Controller Configuration (Settings) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.13.2 Circuit Board and Electronic Component Handling . . . . . . . . . . . . . . . . . 89
4.13.3 Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Section 5 30–200 Amp Standard-TransitionTransfer Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
5.2 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
5.3 Operator Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
5.4 Main Contact Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
5.5 Coil Control Contact Test and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
5.5.1 Coil Control Contact Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
5.5.2 Coil Control Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Section 6 225–400 Amp Standard-Transition Transfer Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
6.1 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
6.2 Main Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
6.3 Operator Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

6.4 Coil Control Contact Test and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
6.4.1 Coil Control Contact Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
6.4.2 Contact Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
6.4.3 Coil Control Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Section 7 150–600 Amp Connection B Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
7.1 Maintenance Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
7.2 Solenoid Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
7.3 Solenoid Assembly Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
7.4 Control Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Section 8 150–400 Amp Programmed-Transition Transfer Switches and Bypass/Isolation
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8.1 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8.2 Main Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8.2.1 Movable Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
8.2.2 Stationary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
8.3 Operator Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
8.3.1 Removing Coil Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
8.3.2 Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
8.3.3 Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
8.3.4 Installing Coil Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
8.4 Control Contact Test & Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
8.4.1 Test and Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
8.4.2 Test Control Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Section 9 600–1200 Amp Transfer Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
9.1 Maintenance Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
9.2 Main and Arcing Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
9.2.1 Arc Chute and Barrier Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
9.2.2 Contact Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
9.2.3 Movable Arcing Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
9.2.4 Movable Main Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
9.2.5 Stationary Arcing Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
9.2.6 Stationary Contact Assembly Replacement . . . . . . . . . . . . . . . . . . . . . . . 141
9.2.7 Arc Chute and Barrier Reinstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
9.3 Solenoid Coil and Solenoid Assembly Replacement . . . . . . . . . . . . . . . . . . . . . . . . 142
9.3.1 Solenoid Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
9.3.2 Solenoid Assembly Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
9.4 Coil Control Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Section 10 600–800 Amp Programmed-Transition and Closed-Transition Bypass/Isolation
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
10.1 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
10.2 Main Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
10.2.1 Tools Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
10.2.2 Remove Barriers and Arc Chutes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
10.2.3 Disassembly of Movable Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
10.2.4 Reassembly of Movable Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
10.2.5 Disassembly of Stationary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
10.2.6 Reassembly of Stationary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
10.3 Operator Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
10.3.1 Removal of Coil Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
10.3.2 Coil Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
10.3.3 Core Tube and Core Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
10.3.4 Core Tube and Core Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
10.3.5 Coil Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
10.3.6 Installation of Coil Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Table of Contents, continued
Table of Contents TP-6460 4/10
Section 11 600–800 Amp Standard Bypass/Isolation Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
11.1 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
11.1.1 Main Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
11.1.2 Stationary Contacts Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
11.1.3 Stationary Contacts Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
11.1.4 Movable Contacts Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
11.2 Transfer Switch Barrier Removal and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
11.2.1 Barrier Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
11.2.2 Barrier Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
11.3 Operator Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
11.3.1 Coil Assembly Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
11.3.2 Coil Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
11.3.3 Core Tube and Core Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
11.3.4 Core Tube and Core Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
11.3.5 Coil Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
11.3.6 Coil Assembly Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
11.4 Control Contact Test and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
11.5 TS Control Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Section 12 1600–3000 Amp Transfer Switches and 1000–3000 Amp Bypass/Isolation Switches . . 175
12.1 Maintenance Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
12.2 Main Contact Inspection and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
12.2.1 Contact Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
12.2.2 Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
12.3 Main and Arcing Contact Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
12.4 Solenoid Assembly Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Section 13 4000 Amp Transfer Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
13.1 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
13.2 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
13.3 Coil Control Contact Test and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
13.4 TS Control Contact Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Appendix A Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Appendix B Message Summaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Appendix C Noise and Wiring Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Appendix D Common Hardware Application Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Appendix E General Torque Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Appendix F Common Hardware Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Appendix G Common Hardware List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204

Kohler