Sale!

John Deere 1760 Wing-Fold Drawn Conservation Planter 8-Row Narrow, 8-Row Wide and 12-Row Narrow Operator’s Manual (OMA54964)

Original price was: $ 45,00.Current price is: $ 35,00.

John Deere 1760 Wing-Fold Drawn Conservation Planter 8-Row Narrow, 8-Row Wide and 12-Row Narrow Operator’s Manual (OMA54964)

Format: PDF (Printable Document)

File Language: English

File Pages: 300

File Size: 105.52 MB (Speed Download Link)

Brand: John Deere

Model: 1760

Type of Document: Operator’s Manual

Categories: ,

Description

John Deere 1760 Wing-Fold Drawn Conservation Planter 8-Row Narrow, 8-Row Wide and 12-Row Narrow Operator’s Manual (OMA54964)

John Deere 1760 Wing-Fold Drawn Conservation Planter 8-Row Narrow, 8-Row Wide and 12-Row Narrow INDEX:

Safety
Safety Signs
Preparing the Planter
Tightening Hardware
Tire Inflation
Lubrication
Drill Shaft Drive Coupler Adjustment
Adjusting Seed and/or Fert. Transmission …
Initial Start Up of Pump
Adjust Transport Wheel Locations
Planter and Tractor Hookup
Hydraulic Pressure
Check Tractor Hydraulic System
Rockshaft Operating Lever Height Stop
Set Tractor Drawbar
Rear Wheel Tread
Check Tire Inflation
Planter and 30—60 Series Tractor Hookup
Rockshaft Operating Lever Height Stop
Set Tractor Selective Control Valve
Selective Control Valve Lever Stop
Installing Hydraulic Lift Hoses
Vacuum Motor Return Coupler
Vacuum Metering System
Planter and 7000 Series Tractor Hookup
Vacuum Meter Pump
Connecting Wiring Hamesses and
Hydraulic Hoses
Motor Return Coupler
Hookup for Vacumeterw
Planter and 8000 Series Tractor Hookup
Set Valve Controls
Motor Return Coupler
Hookup for VacumetorTU

Attaching and Detaching
Attaching to Tractor
Detaching from Tractor
Transporting
Transport Safely
Fold for Transport
Preparing the Vacuum Meter Unit
Choosing Seed Disks
Selecting Seed Disks
Seed Disk Recommendations .
Adjusting Vacuum Meter Baffle
Checking Seed Disk Cell . .
Installing Seed Disk
Adjusting Meter Hub
Installing Knockout Assembly
Installing Double Eliminator
Selecting Correct Vacuum Meter Brush
How to Change Brush
Installing Brush
Check Hydraulic Connections
Preparing the Plateless Meter Unit
Plateless Seed Hoppers
Feed Cup Metering Unit
Soybean Feed Cup
Low-Rate Sorghum
Acid Delinted Cotton and Small Soybeans.
Replace Feed Cup with Finger Pickup
Operating the Planter
General
Row Unit Spacing
Leveling Planter
Frame Flexibility
Half-Width Planting Drive Disconnect
Marker Length
Marker Adjustment

Marker Float Range
Marker Breakaway Bolt
Independent Marker Control
Raising and Lowering Independent
Markers
Raising and Lowering Automatic Markers
Filling Marker Hydraulic Cylinders
Countershaf Drive Coupler Adjustment
Drill Shaft Drive Coupler Adjustment
Changing Planting Depth
Closing Wheel Adjustment when Planting
Small Seeds
Adjusting Closing Wheel Down Force
Walking Gauge Wheel
Centering (Align) Closing Wheel
Filling Seed Hoppers
Emptying Seed Hoppers
Inspection and Cleanout of Seed Hoppers.
HOW to Use Planting Rate Charts
HOW to use Planting Rate Charts
Changing Input Sprocket Combinations
Changing Planting Rate Sprocket
Combinations
Finding Transmission Sprocket Settings
Operating the Vacuum Meter
Vacuum Meter Operating Characteristics
use of Talc Lubricant
Set Vacuum Level .
Zeroing the Vacuum Gauge after
Installation
Vacuum Levels
Corn .
Oil Sunflower
Confectionary Sunflower
Sweet Com
Peanuts
Sugar Beet Seed
Vacuum Meter Seed Charts
Decal Seed Charts
Vacuum Level. Baffle Position and
Vacuum Meter
Operating the Plateless Meter
Finger Pickup Metering unit Operating
Characteristics
Feed Cup Operating Characteristics

Plateless Meter Seed Charts
Planting Small Soybeans with Soybean
Feed Cup
Planting Acid-Delinted Cotton with
Soybean Feed Cup
Checking Seed Population
Checking Seed Population
Drive Wheel Slippage
General Attachments
Unit Down Force Springs
Heavy-Duty Down Force Springs
unit Mounted Coulter
Conservation Furrowers
Tine-Tooth Tillage Attachment
Heavy-Duty Closing Wheels
Rotary Scraper
Row Leveler Chain .
Drive Wheel Rock Guard
Wheel Cover
Row Unit Gauge Wheel Cover
Ballast Attachment
Ballast Attachment
Granular Chemical Attachment
Granular Chemical Attachment
U.S. Measurement
Calibrating Insecticide/Herbicide Meter
Seed Furrow Insecticide Placement
Bracket
Rear Mount Insecticide Spreader
Herbicide Diffuser
Windshield
Tine-Tooth Incorporator
Liquid Chemical Attachment
Liquid Herbicide Pre-Emerge Spray
Attachment
Liquid Fertilizer Attachment
QUIK-FILLTM Liquid Fertilizer
Operation on Hillsides
System Operation
Priming and Initial Start up of Pump
Setting Pump Drive
How to Set Liquid Fertilizer Rates
Checking Fertilizer Rates

Adjusting Pump to Pump Number Setting
Changing Orifice in Special Fitting
Clean Strainer .
Strainer Maintenance
Unit Mount Double-Disk Fertilizer Opener
Adjusting Unit Mounted Fertilizer Opener
Troubleshooti ng
Frame
Markers
Drives
Row Units
Vacuum Meters
Plateless Meter
Fertilizer System
Liquid Fertilizer—Piston Pump System .
Lubrication
Grease
Multiluber Grease
Lubrication Symbols
Roller Chain and Pesticide Sprocket
Lubrication
Alternative Lubricants
Finger Pickup Meters Only
Special Lubricants for Vacuum Seed
Meters
Service
Practice Safe Maintenance
Install Service Stops
Filling Marker Hydraulic Cylinders
service Tires safely
Shear Protection Points
Replacing Marker Breakaway Bolt
Drive Wheels
Cleaning Insecticide and/or Herbicide
Hoppers
Vacuum Gauge Filter
Clean Vacuum Pump Motor Guard
Clean Vacuum Manifold System
Clean Vacuum Meter Drive
Vacuum Meter Inspection and Service
Vacuum Motor Inspection
Installing New Vacuum Seal
Finger Pickup Mechanism
Adjusting Gauge Wheels
Replacing Seed Opener Blades and Seed
Tube
Cleaning Liquid Fertilizer Tanks

Clean Special Fitting Screen
Cleaning Liquid Fertilizer Tank Lid
Fittings
Tighten Liquid Fertilizer Hose Clamps
Storage
Beginning of the Season Service
Service at the End of the Season
Dispose Of Spray Cans Safely
Storing Planter with Liquid Fert.
Attachment
Piston Pump Storage Procedures
To Flush Pump
Crime Prevention Tips
Specifications
Planter Dimensions
Record Serial Number
Index

.John Deere